What was found
LIGHTNING STRIKE TEMP FASTENER AT FS 847+16 BETWEEN STRS 14L + 15L. TEMP FASTENER AT FS 847+16 BETWEEN STRS 14L AND 15L. REMOVED FINISH AT TEMP FASTENER IAW SRM 51-26-00-001-001-A01 REMOVED TEMP FASTENER IAW SRM 51-42-13-001-001-A01. INSTALLED RIVETS IAW SRM TEMPORARY REMOVED 53-0050, TYPE 3B PERMANMENT REPAIR TASK 53-00-00-201-003-A03 AND RESTORE FINISH SRM 51-21-16. PERFORMED CONDUCTUITY TEST OF FUSELAGE SKIN IAW SRM 53-00-00-201-003-A03, TR53-0050 AND NDTM PT 6 53-00-000-252-A01 CONDUCTIVITY READING IS 33.74 PERCENT IACS READING IS WITHIN LIMITS IAW SRM 51-11-20-001-001-A01 PERFORMED EDDY CURRENT INSPECTION OF FUSELAGE SKIN AT FS 847+16, STR 14L-15L IAW NDTM PT 1 51-20-006-250-A01 NO INDICATIONS NOTED AT THIS TIME.