What was found
CORROSION ON LOWER SILL ANGLE AT SERVICE DOOR FS 314. LWR SILL ANGLE CORRODED OUT OF LIMITS IAW SRM 51-21-06-001-001-A01. R & R LWR SILL ANGLE IAW SRM 51-42-06-001-001-A01. REMOVED ATTACH ANGLE FROM WEB CORRODED BEYOND LIMITS REQUIRE REPLACEMENT IAW SRM 51-42-06-001-001-A01/ 51-21-06-001-001-A01. INSTALLED, 4EA ATTACH ANGLES TO WEB FLOOR PROTECTOR IAW SRM 51-42-06-001-001-A01, NEW PARTS INSTALLED.