What was found
FS 333 FRAME IS CORRODED BETWEEN STR 26L AND 26R. REMOVED FS 333 FLOORBOARD SUPPORT ASSY TO FOM IAW SRM 51-42-06. INSTALLED SERVICEABLE FS 333 FLOOR SUPPORT ASSY IAW SRM 51-42-06. REMOVED CORRODED FRAME SEGMENT AT FS 333 IAW SRM 51-42-06 AND 51-42-21. INSTALLED NEW FS 333 FRAME SEGMENT IAW SRM 51-42-06, 51-42-21 AND 51-77-00. PAINTED REPAIR IAW SRM 51-25-01 AND APPLIED CORROSION INHIBITING COMPOUND IAW MM 51-25-56-390-802.