What was found
2 EA FASTENERS, LOCATED AT JUST FWD OF FS 559+112, STR 23R ON EXTERNAL SKIN HAVE FILOFORM CORROSION AROUND FASTENER HEADS. FOUND CORROSION UNDER 6 MORE ROWS OF FASTENERS FWD OF FS 559+112. REMOVED 12 EA RIVETS AND REMOVED CORROSION IAW SRM 51-21-06. MAX MATERIAL REMOVED .0035". REPAIRED DAMAGE IAW EA 32-2015-121. FOUND CORROSION ON DOUBLER AT FS 559+112 JUST ABOVE STR 23R. REMOVED 2 EA FASTENERS AND REMOVED CORROSION IAW SRM 51-21-6. REPAIRED DAMAGE IAW EA 32-2015-122. EA 32-2015-121 HAS BEEN ACCOMPLISHED AND ALL STEPS HAVE BEEN DOCUMENTED AND SIGNED FOR ON A NON-ROUTINE WORK CARD.