What was found
WHILE REMOVING CORROSION ON BS 364 INTERCOSTAL S26R FOUND CORROSION ON STRINGER S26R BETWEEN FS 364-FS 349. HEAVY PITTING CORROSION ON STR 26R BETWEN FS 364-FS 349 EXCEEDING LIMITS OF SRM 53-21-03-101-006-A02. STARTED REMOVAL OF STR 26R REF SRM 51-42-06-001-A01. CONTINUED AND COMPLETED REMOVAL OF STR 26R FROM FS 364- FS 333 REF: SRM 51-42-06-001-001-A01, SEE ITEM 6 FOR INSTALLATION OF SERVICEABLE STR. REMOVED INTERCOSTAL AT FS 364-FS 349, STR 26R FOR FOM REMOVED 2 EA CLIPS 1 AT FS 349 AND 1 AT FS 333 STR 26R TO FOM REF SRM 51-42-06-001-001-A01. INSTALLED STRINGE CLIP AT FS 333 STR 26R IAW SRM 51-42-06-001-001-A01. REINSTALLED RIVETS AT FS 349 BETWEEN STRINGER 27 AND 25R IAW SRM 51-42-06-001-001-A01. REMOVED STR 26R SPLICE AT FS 333 SPLICE FOUND CORRODED REF: SRM 51-42-06-001-001-A01. LOCATED AND DRILLED HOLES IN NEW SERVICEABLE STR 26R SPLICE AT FS 333 IAW SRM 51-40-11-001-001-A01. INSTALLED STRINGER SPLICE IAW CRJ900 SRM 51-42-06-001-001-A01. INSTALLED SERVICEABLE STR 26R REF: SRM 51-42-06-001-001-A01. LOCATED AND DRILLED HOLES IN NEW SERVICEABLE STR 26R BETWEEN FS 333 AND 364 IAW SRM 51-40-11-001-001-A01. INSTALLED STRING 26R IAW SRM 51-42-06-001-001-A01.