What was found
WHILE PERFORMING EVALUATION ON SERVICE DOOR SILL MOUNTING ANGLE, FOUND UPPER MOUNTING ANGLE TO BE CORRODED. REMOVED UPPER MOUNTING ANGLE FROM SERVICE DOOR DUE TO IT BEING OUT OF LIMITS IAW SRM 53-21-23-101-001-A02 AND 51-42-06-001-001-A01. INSTALLED NEW ANGLE MOUNT ON SERVICE DOOR SILL IAW SRM 51-42-06-001-001-A01.