What was found
FIRST FLIGHT OF DAY, EMERGENCY LIGHTS WOULD NOT ILLUMINATE. FOUND F/A EMERGENCY LIGHT GUARDED SWITCH IN ON POSITION. RECONFIGURED SWITCH TO NORMAL, CHARGED EMERGENCY LIGHT POWER SUPPLY IAW SDS 33-50-00, DISCREPANCY NO LONGER EXISTS, IAW MCC, NO FURTHER ACTION IS REQUIRED .