What was found
STRINGER 3L UPPER AND LOWER ATTACH ANGLE CRACKED JUST AFT OF FS 280. R & R STRINGER 3L UPPER & LOWER ATTACH ANGLES WITH NEW SERVICEABLE ANGLES PN 600-31057-19 AND 600-31057-20 IAW DWG 600-31057 AND SRM AND SRM 51-42-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER 3L UPPER AND LOWER ATTACH ANGLE CRACKED JUST AFT OF FS 280. R & R STRINGER 3L UPPER & LOWER ATTACH ANGLES WITH NEW SERVICEABLE ANGLES PN 600-31057-19 AND 600-31057-20 IAW DWG 600-31057 AND SRM AND SRM 51-42-21.