What was found
REAR PRESSURE BULKHEAD WEB THAT SURROUNDS THE LINTEL ATTACHMENT FITTING, HAS INDICATION NOTED, APPROXIMATELY .500" IN LENGTH 90 PERCENT FSH FAILED NDT INSPECTION. COMPLIED WITH EC/TC REO 601R-53-61-1230 & GREO 601R-53-61-1230, REV F.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
REAR PRESSURE BULKHEAD WEB THAT SURROUNDS THE LINTEL ATTACHMENT FITTING, HAS INDICATION NOTED, APPROXIMATELY .500" IN LENGTH 90 PERCENT FSH FAILED NDT INSPECTION. COMPLIED WITH EC/TC REO 601R-53-61-1230 & GREO 601R-53-61-1230, REV F.