What was found
LOWER PAX DOOR SILL BS 310 - 349 FOUND CORRODED OUT OF LIMITS IAW SRM 53-00-00. REMOVED THE DOOR SILL ANGLE IAW SRM 51-42-06, 51-42-13 AND 51-42-21. LOCATED AND DRILLED A NEW DOOR SILL ANGLE IAW SRM 51-40-11. INSTALLED THE DOOR SILL ANGLE IAW SRM 51-42-06 AND 51-42-21.