What was found
FS 605.00 FRAME HAS CORROSION FROM STR 26R TO 22L. UNDER FURTHER INVESTIGATION FOUND DAMAGED AREA TO BE OUT OF LIMITS IAW SRM 53-00-00, FIG 102, SHEET 2. INSTALLED NEW SERVICEABLE FS 605.00 FRAME, PN 601R36026-27 IAW SRM 51-42-06/51-40-11/51-42-21. REMOVED LT AND RT POST THAT ATTACH TO FS 605 AND TRANSVERSE BEAM IAW SRM 51-42-21. INSTALLED LT & RT POSTS IAW SRM 51-42-21. LOCATED & DRILLED NEW FRAME, PN 601R36026-27 AT FS 605.00, STR 26R TO 22L IAW SRM 51-40-11.