As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RT FLOOR SILL DOUBLER IS CORRODED BETWEEN FS 310-319. UPON FURTHER INVESTIGATION, FOUND FLOOR SILL DOUBLER TO BE OUT OF LIMITS, REQUIRES REPLACEMENT. REMOVED FLOOR SILL DOUBLER IAW SRM 51-42-06. RECEIVED NEW SERVICEABLE FLOOR SILL DOUBLER. LOCATED AND DRILLED NEW SERVICEABLE DOUBLER IAW SRM 51-40-11. INSTALLED DOUBLER IAW SRM 51-42-06.