What was found
CORROSION AT NUMEROUS POINTS ON INTERCOSTAL FROM BS 310-349 AND STR 20R. BLENDED CORROSION ON INTERCOSTAL FROM FS 310 TO FS 349 ON STR 20R IN REF TO SRM 51-21-06-001-001-A01. REMOVED INTERCOSTAL AND FWD GUSSET IAW SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-A01. CORROSION DAMAGE ON FWD INTERCOSTAL SECTION FROM FS 310 TO 319.70 FOUND TO BE OUT OF LIMITS. LOCATED AND DRILLED FASTENER LOCATIONS IN NEW INTERCOSTAL IAW SRM 51-40-11-001-001-A01. AFTER FURTHER EVALUATION FOUND DAMAGE ON INTERCOSTAL BETWEEN FS 319.70 TO FS 349 TO BE IN LIMITS. REMOVED 1 SUPPORT RAIL, PN SH670.50018-1 TO FOM IN REF TO SRM 51-42-06-001-001-A01. INSTALLED SUPPORT RAIL, PN SH670-50018-1 IAW SRM 51-42-06-001-001-A01 AND DWG NR SH670-31980. REMOVED FWD CLIP TO GAIN ACCESS TO THE INTERCOSTAL IN REF TO SRM 51-42-06-001-001-A01. INSTALLED FWD CLIP TO INTERCOSTAL AND FRAME IAW SRM 51-42-06-001-001-A01 AND DWG SH670-31950. REMOVED OTBD RIVETS THAT ATTACH THE INTERCOSTAL TO STR 20 IN ORDER TO REMOVE INTERCOSTAL IN REF TO SRM 51-42-06-001-001-A01. INSTALLED OTBD RIVETS THAT ATTACH THE INTERCOSTAL TO STR (20) IAW SRM 51-42-06-001-001-A01 AND DWG SH670-31950. REINSTALLED IAW DWG SH0670-31-950 AND SRM 51-42-06-001-001-A01. COMPLETED INSTALL OF INTERCOSTAL FS310-FS319.70 IAW SRM 51-42-06-001-001-A01 AND DWG SH670-31950.