What was found
EXTERNAL POWER RECEPTACLE DOOR TOP LAND DAMAGED, ON FUSELAGE SIDE. CUT AWAY DAMAGED SECTION OF EXTERNAL POWER RECEPTACLE DOOR UPPER LAND, ON FUSELAGE SIDE, CLEANED UP CUTLINES REF EC/TC REO 601R-53-11-009. FABRICATED, DRILLED AND DEBURRED JOGGLED PLATE, PN 601R-53-11-009-1 FROM 2024 T-3 .050" REF REO 601R-53-11-009, REV A. FOUND EXTERNAL POWER RECEPTACLE DOOR NOT PROPERLY LATCHING TO NEW JOGGLED PLATE, TRIMMED .200" FROM LATCH ENDS TO GET DOOR TO PROPERLY LATCH, DAMAGE REPORT WAS SENT TO MFG FOR DISPOSITION. COMPLIED WITH REO 601R-52-45-053. INSTALLED JOGGLE TO EXTERNAL POWER RECEPTACLE DOOR TOP LANDING REF EC/TC REO 601R-53-11-009. RII COMPLIED WITH FOR THIS MAJOR REPAIR IAW GMM 3-3.