Service difficulty report · Floor Support · Cndair CL6002B19

Difficulty date
October 5, 2015
Submitted
October 21, 2015
Operation
Air carrier
Aircraft
N900EV
Make and model
Cndair CL6002B19
Aircraft serial
7608
Aircraft time
30,262 hours, 28,093 cycles
Part
Floor Support
Condition
Corroded
Location
Bs 621-559
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLOORBEAM TOP CAP AT LBL 27 FROM BS 621 - 559.00+64 IS CORRODED IN MULTIPLE AREAS AND AT NUT PLATE LOCATIONS. BLENDED CORROSION IAW SEM 51-21-06, FOUND TO BE OUT OF LIMITS DUE TO 100 PERCENT MATERIAL LOSS AT MULTIPLE NUTPLATE LOCATIONS. REMOVED THE FLOOR BEAM TOP CAP BETWEEN FS 621-FS 559+64 AT LBL 27 IAW SRM 541-42-06, 51-42-21. COMPLIED WITH ECTC REO 601R-53-61-3778 AND GREO 601R-53-61-3778, REV A, DATED: 07/15/2011 AS WRITTEN. LOCATED FASTENERS HOLES TO MATCH EXISTING HOLE SIZE IN NEW BEAM CAP, FS 559+64 TO FS 621 AT LBL27 IAW SRM 51-40-11. INSTALLED NEW SEAT RAIL BEAM, CAP SECTIONAL IAW REO 601R-53-61-3778.