As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RT FLOOR SUPPORT BETWEEN FS 349 AND FS 364 IS CORRODED. REMOVED CORROSION FROM RT FLOOR SUPPORT STRUCTURE BETWEEN FS 349 AND FS 353, RBL 40-RBL 43 IAW SRM 51-21-06-001-001-A01. BLEND DIMENSIONS ARE 2.5" WIDE BY 4" LONG. RECEIVED & COMPLIED WITH REO 670-53-21-783 & EC/TC REO 690-53-21-783 AS REQUIRED.