What was found
CORROSION ON LT FLOOR SUPPORT IN BAGGAGE BAY BETWEEN FS 1000.00 AND FS 1047.00 IN SEVERAL LOCATIONS. BLENDED CORROSION ON LT FLOOR SUPPORT AT FS 1000-1047 FOUND TO BE OUT OF LIMITS IAW REO 670-53-61-913, MEASURED MECHANICALLY WITH DEPTH GAUGE MCN-1235. REMOVED LT FLOOR SUPPORT AT FS 1000.00-FS 1047.00 IAW SRM 51-42-06-001-001-A01, 51-42-13-001-001-A01 AND 51-42-21-001-001-A01. DRILLED FASTENER HOLES AND INSTALLED FLOOR SUPPORT IAW SRM 51-42-06-001-001-A01 51-42-13-001-001-A01, 51-42-21-001-001-A01 AND 51-42-15-001-001-A01 IAW DWG MM670-35655.