What was found
FRAME 533 "I" STRAP DAMAGED. REMOVED LIGHT SURFACE CORROSION AND PAINT AT DAMAGE IAW SRM 51-21-06-001-001-A01, STRAP IS .063" MATERIAL HOLE DAMAGE MEASURED .142". SUBMITTED DAMAGE TO ENGINEERING FOR PERMANENT DISPOSITION. REMOVED "I" STRAP/LOWER JOINT PLATE AND 5 EA ADDITIONAL FASTENERS TO GAIN ACCESS TO DISCREPANT AREA FOR ENGINEERING SUBMITTAL COMPLY WITH DISPOSITION WHEN RECEIVED. RECEIVED REPLACEMENT "I" STRAP JOINT PLATE AND TRANSFERED DRILLED MOUNTING HOLES IAW SRM 51-40-11-001-001-A01. RECEIVED REO 670-53-31-355, REV DATED 2015-10-31. FINISHED COUNTERSINKING AND INSTALLED REMAINING FASTENERS, REF: REO 670-53-31-355, REV AND DWG SH670-33750, REV V SRM 51-42-21-001-001-A01 AND 51-42-22-001-001-A01. RECEIVED AND COMPLIED WITH ECTC REO 670-53-31-355, REV DATED 10-31-15.