Service difficulty report · Floor Support · Cndair CL6002B19

Difficulty date
October 31, 2015
Submitted
November 20, 2015
Operation
Air carrier
Aircraft
N878AS
Make and model
Cndair CL6002B19
Aircraft serial
7590
Aircraft time
30,579 hours, 28,158 cycles
Part
Floor Support
Condition
Corroded
Location
Bs 559
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

R/T FLOOR SILL CORRODED OF FS 559.48 - FS 559.64. REMOVED CORROSION FROM RT FLOOR SILL AT FS 599+48-559+64 AND WAS FOUND THAT NO DAMAGE LIMITS ARE PROVIDED, FOUND TO BE OUT OF LIMITS IAW SRM 53-51-43. BLEND AREA FOUND TO BE WITHIN THE ALLOWABLE DAMAGE LIMITS OF REO 601-53-00-526, REF ATED 22 MAY 2013. COMPLIED WITH ECTC REO 601R-53-00-526 01 AND GREO 601R-53-00-526, REV DATED 05/22/2013 AS WRITTEN. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR IAW SOP 5702.