What was found
STR 25R BETWEEN FS 295-310 CORRODED AT HYD LINE STANDOFF CORRODED. REMOVED CORROSION IAW SRM 51-21-06-001-001A01, DETERMINED OUT OF LIMITS IAW SRM 53-21-03-101-002-A01 10 PERCENT MATERIAL LOSS. BEGAN REMOVAL OF STR 25R BETWEEN FS 280-333 BY REMOVING RIVETS COMMON TO STR AND SKIN IAW SRM 51-42-06-001-001-A01 AND SPLICE AT FS 333. COMPLETED REMOVAL OF STR 25R BETWEEN FS280-333 IAW SRM 51-42-06-001-001 A01. BEGAN INSTALLATION OF STR 25R BETWEEN FS 280-333 BY INSTALLING RIVETS COMMON TO STR AND SKIN IAW SRM 51-42-06-001-001-A01. FOUND STRINGER SPLICE AT STR 25R, FS 333 CORRODED BEYOND LIMITS IAW SRM 53-21-03-101-002-A01. LOCATED HOLES AND INSTALLED NEW SERVCABLE STRIG SPLICES AT FS 333 STR 25R IAW SRM 51-42-06-001-001 A01 DWG SH670-32420. LOCATED AND DRILLED HOLES FOR STR TO FRAME CLIPS INTO STR 25R AT FS 295 AND 310 IAW SRM 51-40-11-001-001 A01. LOCATED HOLES AND INSTALLED STR CLIPS AT STR 25R, FS 319 AND 333 IAW SRM 51-42-06-001-001 A01 DWG SH670-32420. INSTALLATION OF STR 25R COMPLETE.