As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION AROUND 3 SCREW HOLES ON RBL 9 FLOORBEAM AND PANEL 282LRF SUPPORT STRUCTURE AT FS 559.96. REMOVED CORROSION IAW SRM 51-21-06. EVALAUTED BLEND AREA AND FOUND TO BE WITHIN THE ALLOWABLE LIMITS OF REO 601R-53-00-005, FIGURE 1. COMPLIED WITH REO601R-53-00-005. THIS IS A MAJOR REPAIR. THIS REPAIR HAS BEEN RECLASSIED AS A MAJOR REPAIR IAW EC/TC REO 601R-53-00-005.