What was found
AC EXTERIOR POWER RECEPTACLE DOOR LANDING DAMAGED. CUT AWAY THE DAMAGED PORTION OF THE DOOR LANDING, PN:600-33042-145 AS SHOWN ON SHEET 2 IAW GREO 601R-53-11-009, REV A. FABRICATED DOOR LANDING REPAIR JOGGLE PLATE, PN:601R-53-11-009 -1, FROM 2024-T3, .050", BATCH 1852686 AS SHOWN ON SHEET 2 IAW GREO 601R-53-11-009, REV A. RESTORED FINISH TO A032 IAW SRM 51-21-16 & GREO 601R-53-11-009, REV A. RESTORED THE SELF-CONTOURING GASKET IAW SRM 51-23-16 & IAW GREO 601R-53-11-009, REV A. INSTALLED CHERRY MAX RIVETS IAW SRM 51-42-13 & GREO 601R-53-11-009, REV A. ALL OTHER DETAILS IAW DWG. REPLACED EXT POWER RECEPTACLE SUPPORT MEMBER, PN: 600-33283-33 IAW GREO 601R-53-11-009, REV A WITH CHERRY MAX RIVETS CR3213 IN LIEU OF MS20470 AD. VERIFIED ALL REQUIREMENTS OF EC/TC REO 601R-53-11-009, REV 0 & GREO 601R-53-11-009, REV A, HAVE BEEN COMPLIED WITH. JOB COMPLETE. CLASSIFIED AS A MAJOR REPAIR IAW SOP 5702.