What was found
PASSENGER DOOR SURROUND, SILL AREA, HAS CORROSION . NEED EVALUATION. REMOVED FASTENERS IN MID CAP ANGLE AND KICKPLATE ANGLE TO ACCESS CORROSION REMOVAL PROCESS IAW SRM 51-42-06-001-001-A01. TRANSFERED ALL EXSITING FASTENER LOCATIONS NOT SERVICABLE MID CAP ANGLE AND KICKIPLATE AND INSTALLED NUTPLATES AS REQUIRED IAW SRM 51-40-11-001-001-A01 AND 51-42-06-001-001-A01. UPON REMOVAL OF MID CAP ANGLE TO ACCESS CORROSION REMOVAL ON KICKPLATE HEAVY CORROSION WAS FOUND DEEMING BOTH PARTS, REPLACEMENT REQUIRED. INSTALLED NEW KICKPLATE IAW SRM 51-42-06-001-001-A01. REMOVED CORROISON ON PAX DOOR MID CAP ANGLE AND KICKPLATE ANGLE IAW SRM 51-12-00-001-001A-01, TR 51-0050 AND 51-21-06-001-001-A01. CORROISON FOUND ON PAX DOOR MID ANGLE AND KICKPLATE WAS FOUND OUT OF LIMITS IAW SRM 51-12-00-001-001-A01. KICKPLATE ANGLE REQUIRED SEALING AND RESTORATION OF FINISH. INSTALLED THE FWD AND AFT AND MID CAP ANGLES IAW SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01 AND DWG SH670-31080.