As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM CAP CORRODED BETWEEN FS 554.00 +64 AND FS 559.0+45 AT RBL9. REMOVED CORROSION FROM FLOORBEAM AT RBL 9 BETWEEN FS 559.00+48-559.00+64 IAW SRM 51-21-06. REPAIR OR REPLACE BLEND AREA OUT OF ALLOWABLE LIMITS IAW SRM 53-00-00. COMPLIED WITH SRM FLOOR SUPPORT STRUCTURE REPAIR NO 1 53-00-43.