SERVICE DOOR SILL HAS SEVERAL AREAS OF CORROSION. ANGLE WAS FOUND TO BE OUT OF LIMITS. R & R LOWER MOUNTING ANGLE AND LOWER SILL ANGLE AT SERVICE DOOR SILL IAW SRM 51-42-06-001-001-A01, SRM 51-42-13-001-001-A01, SRM 51-42-21-001-001-A01, SRM 51-42-15-001-001-A01 AND DWG SH670-31950.