What was found
RT WING PLANK CRACKED AT WS 148.019. REMOVED RT INBD LOWER T/E INBD OF "PIE PANEL" IAW SRM 51-42-21, 51-42-06. INSTALLED INBD LOWER T/E INBD OF "PIE PANEL", REF SRM 51-42-06 AND SRM 51-42-21 AND DWG 601R10225. COMPLIED WITH ECTC REO 601R-57-21-130 01 AND REO 601R-57-21-130, REV K DATED 11/27/2013 AS WRITTEN. COMPLIED WITH ECTC REO 601R-57-21-131 AND REO 601R-57-21-131 IAW B DATED 11/28/2013 AS WRITTEN. INSTALLED -10 REPAIR STRAP AS REQUIRED, REF SRM 51-42-21 AND REO 601R-57-21-130-01.