As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION FOUND AROUND SCREW HOLES AT FS 559.00+69 AND 559.00+80 RBL9 ON OTBD SIDE. REMOVED DAMAGE AND FOUND NOT WITHIN LIMITS IAW SRM 53-00-00 AT FS 559+69 AND 559+80 RBL9. REPAIRED FLOORBEAM AT FS 559.00+69 TO 559.00+80 RBL9 IAW SRM 53-00-43 FLOOR SUPPORT STRUCTURE REPAIR NR 1 PROCEDURE 59 REAPPLIED CK. REMOVED FOR REPAIR AND DWG 601R311119.