CORROSION FOUND ON RT FLOOR SILL BETWEEN FS559.00-559.00+16. REMOVED CORROSION IAW SRM 51-21-06, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00-01. REMOVED INTERCOSTAL FOR REPLACMENT. DRILLED UP NEW INTERCOSTAL. REF: SRM 51-42-06 AND 51-40-11. DWG: 601R38842, REV B. INSTALLED RT FLOOR SILL NEW SERIVCABLE AT FS559.00-559.00+16 IAW DWG 601R38842 AND SRM 51-42-06-00 AND 51-42-21-00 AND 51-41-00-00.