What was found
FS 202.75 WINDSHIELD CENTER POST LT LOWER FITTING CRACKED AT WL 110.00. REMOVED CRACKED FITTING AND INSTALLED NEW FITTING AT FS 202.75 LOWER LT CENTER POST IAW SRM 51-42-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FS 202.75 WINDSHIELD CENTER POST LT LOWER FITTING CRACKED AT WL 110.00. REMOVED CRACKED FITTING AND INSTALLED NEW FITTING AT FS 202.75 LOWER LT CENTER POST IAW SRM 51-42-21.