As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION FOUND ON PRESSURE FLOOR JUST FWD OF FS 559 ON RT SIDE. BLENDED CORROSION FWD OF FS 559 ON CROSSBEAM ABOVE PRESSURE FLOOR IAW SRM 51-21-06-00. EVALUATED BLEND AREA FOUND TO BE ON STEP AT FS 559.00 BETWEEN RBL36-RBL45 OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-41-43-01. R & R DISCREPANT PART AS NEEDED REF DWG 601R31025. DRILLED UP AND INSTALLED NEW SERVICABLE STRAP IAW SRM 51-42-06-00 & DWG 601R31025 & SRM 51-40-11-00.