As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON PRESSURE FLOOR SUPPORT BEAM IN MULTIPLE LOCATIONS BETWEEN FS409.00+128 AND FS559.00 AT RBL9. BLENDED CORROSION IAW SRM 51-21-06. BLENDED AREA IS OUT OF ALLOWABLE LIMITS IAW SRM 53-00-00. COMPLIED WITH REO PL 601R-53-41-19980. COMPLIED WITH REO 601R-53-41-1997. REPAIRED IAW ECTC 601R-53-41-1997.