As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM CAP AT RBL9 SCREW HOLES CORRODED BETWEEN FRAME BS 409+9 - 409+35. BLENDED CORROISON DAMAGE IAW SRM 51-21-06. FOUND DAMAGE TO BE OUT OF LIMITS IAW SRM 53-00-00 WITH NO MATERIAL REMAINING. REMOVED FASTENERS IN FLOORBEAM COMMON TO REPAIR IAW SRM 53-00-43, REPAIR NR 2. COMPLETED FLOORBEAM, REPAIR NR 2 IAW SRM 53-01-43. REPAIR NR 2.