As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM AT FS 559 AND BETWEEN RBL 27 AND RBL 46 CORRODED. REMOVED CORROSION ON FLOORBEAM IAW SRM 51-21-06. FOUND OUT OF LIMITS IAW SRM 53-00-00-07. REMOVED FLOOR CROSSBEAM AT FS 559 AND STARTED DRILLING NEW CROSS BEAM IAW SRM 51-42-06, PAR 8 AND 51-40-11. DRILLED UP NEW CROSSBEAM AT FS 559, RBL 27 AND RBL 46 IAW SRM 51-40-11. INSTALLED SERVICEABLE CROSSBEAM STRAP AT FS 559, BETWEEN RBL 27 AND RBL 46 AS NEEDED REF SRM 51-42-06 AND DWG 601R31025.