What was found
CORROSION AROUND NUTPLATE HOLES ON FLOOR SUPPORT RBL9, F/S 409.80+32-409.00+48. REMOVED THE CORROSION IAW SRM 51-21-06 AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00. REPAIRED THE FLOOR SUPPORT IAW SRM 53-00-43.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AROUND NUTPLATE HOLES ON FLOOR SUPPORT RBL9, F/S 409.80+32-409.00+48. REMOVED THE CORROSION IAW SRM 51-21-06 AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00. REPAIRED THE FLOOR SUPPORT IAW SRM 53-00-43.