What was found
CORROSION FOUND ON FLOORBEAM AROUND SCREW HOLE. BLENDED AND REMOVED CORROISON IAW SRM 51-21-06-00. BLENDED AREA IS OUT OF ALLOWABLE LIMITS IAW REO 601R-5-53-00-005.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON FLOORBEAM AROUND SCREW HOLE. BLENDED AND REMOVED CORROISON IAW SRM 51-21-06-00. BLENDED AREA IS OUT OF ALLOWABLE LIMITS IAW REO 601R-5-53-00-005.