What was found
BURNS ON STR 23L BETWEEN FS 295 - 310. REMOVED DAMAGE FROM BURNS ON STR 23L BETWEEN FS 295/310 IAW SRM 51-12-00. DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-00-31. MATERIAL REMOVED WAS .600"L X .600"W X .009" DEEP. NR 2: .600"L X .600"W X .009" DEEP, NR 3: .600"L X .600"W X .009" DEEP. MEASURED REMAINING MATERIAL THICKNESS AT DAMAGE LOCATION R(1), R(2), R(3) IAW SRM 51-12-00 AND SRM 53-21-31. MEASURED REMAINING MATERIAL AT LOCATION R(1) = 0.054", R(2) = 0.054", R(3) = 0.054". COMPLIED WITH DISPOSITION IAW EA 25-2016-078. INSTALLED 01 FASTENER. THIS IS CONSIDERED A MAJOR REPAIR IAW GMM 5-3.