What was found
LT AND RT WINDSHIELD CENTER POST LOWER FITTINGS CRACKED. R & R LT AND RT WINDSHIELD CENTER POST LOWER FITTINGS IAW SRM TASK 51-40-11 AND 51-42-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT AND RT WINDSHIELD CENTER POST LOWER FITTINGS CRACKED. R & R LT AND RT WINDSHIELD CENTER POST LOWER FITTINGS IAW SRM TASK 51-40-11 AND 51-42-21.