As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION AROUND FLOORBOARD SCREW HOLE ON RBL9 AND AT FS 409+40. REMOVED CORROSION AT FS 409+40, RBL 9 INBD SIDE IAW SRM 51-21-06, AND FOUND TO HAVE COMPLETE MATERIAL LOSS. REPAIR FLOORBEAM SUPPORT STRUCTURE IAW SRM 53-00-43. REPAIRED FLOORBEAM AT 409+40 IAW EO 600-53-0772.