FORWARD EMERGENCY FLOOR LIGHT AND EXIT SIGN ARE INOPERATIVE. R & R ELECTRICAL CONNECTOR IAW ESPM 20-11-00 20-17-10 ON WIRES LY6022 AND LY32A22. R & R EMERGENCY LIGHTS BATTERY NR 2 PACK IAW AMM 33-51-04-400-801, 33-51-04-000-801, IPC 33-51-04, ITEM 17. OPS TEST CHECKED GOOD.