What was found
LT MLG TRUNNION AFT BUSHING BORE AUXILIARY HOLE DIAMETER IS OUT OF LIMITS. REAMED LT MLG AFT TRUNNION LUG TO FIRST OVERSIZE IAW ECTC REO 601R-57-21-003. INSTALLED 1ST OVRSIZE BUSHING INLT MLG AFT TRUNNION IAW ECTC REO 601R-57-21-003.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT MLG TRUNNION AFT BUSHING BORE AUXILIARY HOLE DIAMETER IS OUT OF LIMITS. REAMED LT MLG AFT TRUNNION LUG TO FIRST OVERSIZE IAW ECTC REO 601R-57-21-003. INSTALLED 1ST OVRSIZE BUSHING INLT MLG AFT TRUNNION IAW ECTC REO 601R-57-21-003.