As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RT MLG TRUNNION AFT BUSHING AUX BORE HOLE DIAMETER IS OUT OF LIMITS. REMOVED RT MLG AFT TRUNNION LUG TO TO FIRST OVERSIZE IAW ECTC REO 601R-57-21-003. INSTALLED 1ST OVERSIZE BUSHING IN RT MLG AFT TRUNNION IAW ECTC REC 601R-57-21-003 AND GREO 601R-57-21-003, EV B.