As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION SERVICE DOOR FLOOR SILL. LOWER ANGLE BEYOND ALLOWABLE LIMITS IAW SRM 53-21-23-101-001-A02, REPLACE WHEN PAT RECEIVED. REMOVED LOWER ANGLE IAW SRM 51-42-06 AND DRILLED NEW ANGLE IAW SRM 51-40-11-001-001-A01 AND DWG SH670-31950. INSTALL SERVICE DOOR FLOOR SILL ANGLE IAW SRM NEW 57-42-06-001-001-A01 AND DWG SH670-31950.