What was found
CARGO FLOORBEAM HAS CORROSION AT LBL9 AT FS1031. REMOVED CORROSION ON LBL9 AT FS 1031 IAW SRM 51-21-06-00-0001-A01. FOUND TO BE OUT OF LIMITS DUE TO 50 PERCENT MATERIAL LOSS WHERE NO DAMAGE IS ALLOWED. COMPLIED WITH EO 900-53-0029 IAW GREO 670-53-00-029, REV A.