What was found
MULTIPLE BURN MARKS ON AFT EQUIPMENT BAY DOOR AT FWD EDGE LT SIDE. FOUND TO BE OUT OF LIMITS IAW EC/TC REO 601R-53-00-115 REV H. COMPLIED WITH DISPOSITION EA 25-2016-199 , SECTION 1 PERMANENT REPAIR , ITEMS 5-9.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MULTIPLE BURN MARKS ON AFT EQUIPMENT BAY DOOR AT FWD EDGE LT SIDE. FOUND TO BE OUT OF LIMITS IAW EC/TC REO 601R-53-00-115 REV H. COMPLIED WITH DISPOSITION EA 25-2016-199 , SECTION 1 PERMANENT REPAIR , ITEMS 5-9.