What was found
MULTIPLE DENTS IN FUSELAGE SKIN, FS 589.00-FS 605.00, STR 24R-26R, MARKED. EVALUATED DENT DAMAGE AT DISCREPANT LOCATION AND FOUND OUT OF ALLOWABLE LIMITS, SRM 53-61-31-01 AND SRM 53-00-31-01, FIG 103. COMPLIED WITH ENGINEERING DISPOSITIONS STS EA 32-2016-166 AND EC/TC EA 32-2016-166. INSTALLED DENT DOT AND DEFECT 811657 IAW GMM 2-59, 2 MAINTENANCE 8/20/16.