What was found
DURING C CHECK FOUND FRAME 319 CORRODED BETWEEN STR 25R & 24R. MTC REPAIRED FRAME PER SRM 53-00-06-201-001-A03 & DRAWING SH670-31355.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C CHECK FOUND FRAME 319 CORRODED BETWEEN STR 25R & 24R. MTC REPAIRED FRAME PER SRM 53-00-06-201-001-A03 & DRAWING SH670-31355.