What was found
DURING C CHECK FOUND PAX DOOR UPPER FLOOR SILL CORRODED. MTC R & R FLOOR SILL CAP ANGLE IAW SRM 51-42-06-001-001-A01, 51-42-012-001-001-A01, & DRAWING SH670-31810. ALL DEFECTS CORRECTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C CHECK FOUND PAX DOOR UPPER FLOOR SILL CORRODED. MTC R & R FLOOR SILL CAP ANGLE IAW SRM 51-42-06-001-001-A01, 51-42-012-001-001-A01, & DRAWING SH670-31810. ALL DEFECTS CORRECTED.