What was found
CORROSION FOUND ON FLOORBEAM AT FS 1031 RBL 9. CUT OUT DAMAGED FLOORBEAM AND SPLICED IN NEW SECTION IAW REO 670-53-00-029, EC/TC EO 900-53-10-00004, REO 690-53-61-660 AND EC/TC REO 690-53-61-660.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON FLOORBEAM AT FS 1031 RBL 9. CUT OUT DAMAGED FLOORBEAM AND SPLICED IN NEW SECTION IAW REO 670-53-00-029, EC/TC EO 900-53-10-00004, REO 690-53-61-660 AND EC/TC REO 690-53-61-660.