What was found
ON PAX DOOR SURROUND AT FRAME 15 BETWEEN STRINGERS 15-16L REINFORCEMENT ANGLE FOUND CRACKED. THE ANGLE WAS REPLACED IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON PAX DOOR SURROUND AT FRAME 15 BETWEEN STRINGERS 15-16L REINFORCEMENT ANGLE FOUND CRACKED. THE ANGLE WAS REPLACED IAW SRM 51-40-02.