What was found
SERVICE DOOR AFT SILL CORRODED. SERVICE DOOR AFT SILL REPAIRED AS PER SRM 53-21-10 ITEM 5 FIG 204 SHEET 3. HFEC PERFORMED WITH NO FAULT FOUND.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SERVICE DOOR AFT SILL CORRODED. SERVICE DOOR AFT SILL REPAIRED AS PER SRM 53-21-10 ITEM 5 FIG 204 SHEET 3. HFEC PERFORMED WITH NO FAULT FOUND.